D.5 scanner port – Unitech Hand Held Scanner User Manual

Page 41

Advertising
background image

Page D.5

D.5 Scanner Port:

Enter Group 5

Group Default

0

1

2

3

4

5

6

7

8

9

Terminator:

0

Enter 1

Return (on digits keypad)

2

Field Exit or Right Ctrl 3

None

D1

Code ID: 0 – disable 1 – Enable

Note: This setting doesn’t affect EAN128 Code ID.
EAN128 has its own Code ID setting on page D.7.

D2

Define Code ID:

00–Code 39 Full ASCII
01–Code 39 Standard
02–EAN-13
03–UPC-A
04–EAN-8
05–UPC-E
06–Interleaved 2 of 5
07–Codabar
08–Code 128
09–Code 93
10–Standard 2 of 5

11–MSI Code
12– EAN128
13–Code32 (Italian

harmacy)

14–Delta Code
15–Label Code
16–Plessey Code
17– Code 11(Special)
18–China Postal code

(Toshiba Code)

D3

Scan two digits to
choose a code, then
scan a char. From full
ASCII table to define
ID.

Double Verification:

0 – Off
1~7 – On(Verify 1~7 times)

D4

Scanning Mode:

0Trigger Mode 1– Flashing Mode
2 –Multiscan Mode 3–One Press One Scan
4-–Test Mode 5–Old Laser flash Mode

D5

Label Type:

0 – Positive
1 – Positive and Negative

D6

Aim function for long range laser engine:

0—Disable
1—Enable

D7

Preamble

PP

Postamble

OO

Scan ‘PP\OO’ for Pre\Postamble. Scan characters
from Full ASCII char or Function

Exit

Advertising