3.10.8. Trigger Mode 5

This mode is “multiple shutter pulse width mode”. The camera starts integration of the incoming light from the first

external trigger input falling edge and exposes incoming light until the trigger is inactive. It repeats this sequence for

the N-th (parameter) external trigger input falling edge and then the integration finishes. A Parameter is required and

shall be one or more. (N >= 1)

3.10.9. Trigger Mode 12

Trigger mode 12 is only supported on Fire-i 701/702/810 cameras. The user can capture the multi frame rates with

one trigger signal. The users can control the Gain and Shutter by the Parameter Table which has a range from 1 to 255.

Mode 12 is supported by both H/W trigger and S/W trigger.