Base address: F2F22000h, default baud rate is 57600

Address

Name

Field

Bit

Description

000h Serial_Mode_Reg Baud

Rate

[0..7]

Baud Rate Setting
Write : Set baud rate
Read : Get current baud rate
0: 300 bps 1: 600 bps
2: 1200 bps 3: 2400 bps
4: 4800 bps 5: 9600 bps
6: 19200 bps 7: 38400 bps
8: 57600 bps 9: 115200bps
10: 230400bps Other value reserved.

Char_Length [8..15]

Character length setting
Write: Set data length(must not be 0)
Read : Get data length
7: 7 bits
8: 8 bits
Other values reserved.

Parity- [16..17]

Parity

setting

Write : Set Parity
Read : Get current parity
0: None 1 : Odd 2 : Even

Stop_bit [18..19]

Stop

bits

Write : Set stop bit
Read : Get current stop bit
0: 1 1: 1.5 2: 2.

- [20..23]

Reserved

Buffer_Size_Inq

[24..31]

Buffer Size (Read Only)
This field indicates the maximum size of
receive/transmit data buffer.
If this value=1, Buffer_Status_Control,
SIO_Data_Register Char1-3 should be
ignored

004h Serial_Control_Reg

RE

[0] Receive

enable

Read : Current status
Write : 0 : Disable 1: Enable

TE [1]

Transmit

enable

Read : Current status
Write : 0 : Disable 1: Enable

- [2..7]

Reserved

Serial_Status_Reg

TDRD

[8]

Transmit data buffer ready
Read only
0 : Not ready 1: Ready

- [9]

Reserved

RDRD

[10]

Receive data buffer ready
Read only
0 : Not ready 1: Ready

- [11]

Reserved

ORER

[12]

Receive buffer over run error
Read : Current status