One-shot and multi-shot, Multi-camera auto-sync – Unibrain 501 User Manual

Page 60

Advertising
background image

Unibrain Fire-i 501/511/601/701/702/810 Operation Manual

Page 52


4.4.

One-Shot and Multi-Shot

This camera supports One-Shot and Multi-Shot features. The camera should be in a Iso_disabled mode before the

execution of those commands. If the camera is Iso_enabled mode already, those commands are ignored.

One-Shot (grab one frame) and Multi-Shot (grab 1 ~ 65,535 frames) can be used combined with a hardware trigger

which grabs either one frame or multi frame according to the command respectively.

The command can be executed configuring the following registers.

One-Shot Multi-Shot

Address F0F0061CH Address F0F0061CH

Data 80000000h Data 4000nnnh

nnnn is the number of frames output which can be from any number between 0001h ~ FFFFh.(1~ 65,535)

Priority of the command execution is as follows. Continuous Æ One-shot Æ Multi-shot.

When a command with higher priority is being executed the command with lower priority shall be ignored.

4.5.

Multi-Camera Auto-sync

Not supported in 3.75 fps

In applications incorporating multi camera, there is often a need to synchronize the cameras. Multi-Camera Auto

Synchronization is supported utilizing the FireWire bus time cycle register which is connected on the same FireWire bus.

A maximum of 3 cameras can be auto synchronized.

The video mode of the camera must be set within the limit of a single FireWire bus bandwidth of 400Mbps. Also the

maximum shutter value must be set as per the table below not exceeding the FireWire bus cycle time. Jitter may occur

due to CPU operation timing.

FPS

Fire-i 501/511

Fire-i 601

Fire-i 701/702

Fire-i 810

Max Shutter

Max Shutter

Max Shutter

Max Shutter

Value Time Value Time Value Time Value Time

60

1110

16.5ms

- - - - -

30 1276

33.1ms

1270

32.5ms -

-

-

-

15 1608 66.3ms 1598 65.3ms 1612 66.7ms 1606 66.1ms

7.5 1760 131ms 1758 129ms 1761 132ms 1760 131ms

3.75

1893

264ms

1889

260ms

1895

266ms

1893

264ms

To utilize Auto-sync, please set Bit 31 to Auto-sync Enable, and then check the Bit 27 to verify whether it is ready.

Please refer the details as the following table.

0xF2F10018

Auto-Sync Mode control register
Bit 31 : auto sync enable
Bit 30 : SIO enable mode (0 : custom mode, 1 : IIDC v1.31)

Bit 27 : auto sync complete (read only. 1: ready, 0: not yet auto-sync)