Basic features, vx1505 servers, Vx1505 servers – Unisys NX5820 User Manual

Page 117

Advertising
background image

VX1505 Servers

7017 6300–005

6–11

Table 6–8. Basic Features, VX1505 Servers

VX1505

Servers

4

Processors

2,3,8

Memory

4

10/100

Mbps LAN

Interface

3.5-Inch

1.44-MB

Floppy

Disk Drive

CD-ROM

Drive

DAT

Tape

Drive

7

RAID
9-GB

Hard Disk Drives

5

Min.

Max.

Std.

Std.

Std.

Std.

Std.

Max.

Per Server

1,6,7

1 to 4

0.5-MB

8-GB

2

1

1

0

2

2

Notes:

1. VX1505-BSE includes the basic components listed in Table 6–10. VX1505-BSU contains the

same basic components.

2. VX1505-BSE/-BSU orders required the selection of 1 to 4 of the following:

XER2450-512

Pentium II Xeon CPU, 450-Mhz, 512KB cache

XER2450-1MB

Pentium II Xeon CPU, 450-Mhz, 1MB cache

XER2450-2MB

Pentium II Xeon CPU, 450-Mhz, 2MB cache

XEO3500-512

Pentium III Xeon CPU, 500-Mhz, 512KB cache

XEO3500-1MB

Pentium III Xeon CPU, 500-Mhz, 1MB cache

XEO3500-2MB

Pentium III Xeon CPU, 500-Mhz, 2MB cache

XEO3550-512

Pentium III Xeon CPU, 550-Mhz, 512KB cache

XEO3550-1MB

Pentium III Xeon CPU, 550-Mhz, 1MB cache

XEO3550-2MB

Pentium III Xeon CPU, 550-Mhz, 2MB cache

See Table 6-11

3. All processors with a VX15xx server must be the same style.

4. All VX1505-BSE orders require the selection of the following memory styles (Quantity ordered

must be in increments of four (32 total) and the same type):

DIM5072-128

128MB Memory, EDO, 50ns DIMMs (32 maximum, including
initial)=4.0GB

DIM5072-256

256MB Memory, EDO, 50ns DIMMs (32 maximum, including
initial)=8.0GB

5. Two 9-GB hard disk drives are included with each VX1505-BSE/-BSU package. No additional

drive can be added.

6. A connection package (Table 6-13), optional user access components (Table 6-14), optional

PCT Thru card and software package must be ordered separately.

7. A tape is recommended for back-up. Order the following styles if desired:

PCT12000-DAT

12 GB DAT Tape Drive (Qty. 1)

EXD221-SXR

Tape Drawer (Qty. 1. Drawer will accommodate 2 tapes)

CBL2210-OSM

10 foot SCSI Interface Cable (Qty. 1. Cable is used between the
tape and server RAID adapter.)

OSM1000-PRC

IEC320 Rack to Rack Power Cord (Qty. 1)

8. One or more voltage regulators, style XEO24001-VRM, are required dependent upon the

number of processors installed. A processor terminator, style XER2400-TRM, is required for
each unused processor slot. See Table 6-9.

9. For additional features and enhancement options, reference server specifications

10. For optional hot-swap redundant power supply order component style QR2000101-RPS

(Qty. 1)