Design guidelines for 6041i insert installation – United States Stove Company 6041TP User Manual

Page 15

Advertising
background image

USSC

15

DESIGN GUIDELINES FOR 6041I INSERT INSTALLATION

INSTALLATION AS A BUILT-IN FIREPLACE
A continuous sheet of non-combustible floor protection must be installed underneath the unit to prevent the possibil-

ity of embers falling through to the combustible floor. If the floor beneath the unit is of non-combustible material, the

protector is not required.
See the “Clearance to Combustibles” section of this manual for installation clearances.

Alternative Exhaust Venting

Depending on your installation, you might consider routing your cleanout

tee as illustrated below for ease of cleaning. The access panel in the right

side facade allows you to reach the tee from the front side of the unit if

venting is assembled as shown. The cleanout tee is attached to a 90°

elbow mounted to the unit then rotated at approx. 15-20 degrees. A 12

inch section of “PL” vent is connected to reach the top of the unit to which

a flexible pipe may be attached for further termination through a chimney.

Clearance to combustibles must be considered if this installation is chosen.

A distance of 3 inches must be maintained from the exhaust vent to any

combustible material.

A MINIMUM OF 3 VERTICAL

FEET OF PIPE OUTSIDE THE

HOME IS REQUIRED!