Cabling

• Twisted-pair segments can be Unshielded Twisted Pair (UTP) or

Shielded Twisted Pair (STP) cabling. The cable must comply with the

IEEE 802.3 10/100/1000Base-T standard for Categor y 5e/6. The

cable between the conver ter and the link par tner (switch, hub,

workstation, etc.) must be 100 meters (328 ft.) or less in length.

• Fiber segments using Single Mode connectors must use 9/125µm

Single Mode fiber cable. The maximum link distance in full duplex

operation is 10 Kilometers (6.2 miles). The maximum link distance

in half duplex operation is 412 meters (1352 ft).

• The

maximum

distance

of

fiber

segments

using

Multi-Mode

connectors measures 550 meters (1804 ft.) with 50/125µm or

62.5/125µm Multi-Mode fiber cable.

Network Connection

A. Select the appropriate length Categor y 5e or 6 twisted pair cable.

Connect one end of the twisted pair cable to the RJ-45 connector

on the conver ter and the other end of twisted pair cable to the RJ-

45 connector on any 10/100/1000Base-T device.

B. Connect one end of a fiber jumper to the SC connector on this

conver ter and the other end of the fiber jumper to the SC

connector on the other 1000Base-SX/LX device.

C. Attach the power adapter DC jack to the conver ter. Verify that the

Power LED is on.

D. Verify that the UTP “LK/ACT” LEDs light when cable connection is

installed correctly. Verify that Fiber “LK/ACT” LED blinks to indicate

network activity.

Troubleshooting

• Verify that you are using the right power adapter, DC 5V, 2A

(minimum). Using a power adapter with DC output greater than 5V

could result in damage to the unit and/or personal injur y.

• Confirm the proper UTP/Fiber cable is being used. The Single Mode

conver ter must use Single Mode fiber optic cable.

Key Features

Standards:

IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TX

IEEE 802.3ab 1000BaseT,

IEEE 802.3z 1000BaseSX/LX standards

IEEE 802.3x Flow Control and Back pressure

LED Indicators: Power (Green)

UTP SPD: 1000Mbps /100Mbps / 10Mbps

Lnk/Act: UTP /FIBER

FDX: UTP: Full-Duplex mode / Half-Duplex or Link down

FIBER: Full-Duplex mode / Link down

Connector:

Fiber: Duplex SC

RJ-45 Socket: CAT-5e (10/100/1000Mbps) Twisted Pair

cable Auto MDI/MDI-X and Auto-Negotiation Function

Suppor t

Fiber parameters:

Fiber Core: Multi-Mode (62.5/125um, 50/125um)

Single-Mode (9/125um)

Wavelength: 850nm(Multi-mode),

1310nm(Single-mode)

Fiber Distance: 550m (Multi-Mode Fiber)

10km (Single-Mode Fiber)

Link Loss Forward:

Copper to Fiber: If copper por t link down, then media

conver ter will forced fiber to link down.

Fiber to Copper: If Fiber por t link down, the media

conver ter will forced copper por t to link down.