The ice cube thickness control is factory set for best overall perfor-
mance. The factory setting is designed to maintain an ice bridge of
approximately 1/16" to 1/8" under normal conditions resulting in a
dimple of approximately 1/4" to 1/2" in depth (see Figure 28). A fuller
cube with less of a dimple results in a thicker ice bridge. As the ice
bridge becomes thicker, the tendency for the cubes to stay together as
a slab increases. A bridge thicker than 1/8" may cause cubes to over-
fill the ice bucket.

Figure 28 – Cube Types

To adjust:

Disconnect power to the ice maker before making
any ice thickness adjustments.

1.

Disconnect power to the unit.

Figure 29

ICE003

ACCESS PANEL SCREWS

I

C

E

O F F

C L N

!

WARNING

GOOD

BRIDGE

TOO THIN

BRIDGE

TOO THICK

DIMPLE

TOO DEEP

LITTLE OR

NO DIMPLE

1/4" TO 1/2"

DIMPLE

1/16" TO 1/8"

ICE BRIDGE

BAD

ICE002

Body_UM.qxd 12/17/04 9:16 AM Page 25