U-Line CLR2060 User Manual

Page 39

Advertising
background image

37

Problem

Possible Cause

Remedy

Unit runs but

Scale and mineral

Clean unit. See

produces very

buildup in unit.

MAINTENANCE.

little ice.

Inadequate airflow at

Remove items blocking

(continued)

the front of the unit.

airflow.

Ice is slow to

Ice-making system

Run unit through

release or does

is dirty.

automatic clean cycle.

not release from

See MAINTENANCE.

the evaporator.

Unit is not level.

See LEVELING THE
UNIT.

Low air temperature

Surrounding air

around unit.

temperature must be
at least 50°F (10°C).

Poor ice quality.

Poor incoming water

Consult a qualified

(soft or unclear)

quality.

plumber to test the
water quality and
recommend appropriate
treatment.

Ice-making system is

Run unit through

dirty.

automatic clean cycle.
See MAINTENANCE.

Unit produces

Low water level.

Check to see that

shallow or

overflow tube is fully

incomplete cubes,

seated.

or the ice fill
pattern on the

Hot incoming water.

Connect the unit to a

evaporator is

cold water supply.

incomplete.

See INSTALLATION.

Incorrect incoming

Water pressure must

water pressure.

be 20-120 psi.

Unit is not level.

See LEVELING THE
UNIT.

Body_UM.qxd 12/17/04 9:16 AM Page 37

Advertising