Model 5100-02-IT Combustible Gas Sensor Module

Page: 38

Command Specific Response Data Bytes:

Byte

Format

Description

0

Unsigned-8

Returns new Alarm Level.


Command 132: Set Warning Level

Request Data Bytes:

Byte

Format

Description

0

Unsigned-8

Warning level, range 0 to 60. Default is 20.

Command Specific Response Data Bytes:

Byte

Format

Description

0

Unsigned-8

Returns new Warning Level.

Command 133: Set Alarm Relay Action

Request Data Bytes:

Byte

Format

Description

0

Unsigned-8

0=Latching (default)
2=Non-Latching

Command Specific Response Data Bytes:

Byte

Format

Description

0

Unsigned-8

Returns new Alarm Relay Action value

Command 134: Set Warning Relay Action

Request Data Bytes:

Byte

Format

Description

0

Unsigned-8 0=Latching

2=Non-Latching (default)

Command Specific Response Data Bytes:

Byte

Format

Description

0

Unsigned-8

Returns new Warning Relay Action value

Command 135: Reset Alarms

This command will reset any alarm relays that have been latched, providing the alarm condition is no longer
present on the sensor.

Request Data Bytes:

None

Command Specific Response Data Bytes: None


Command 136: Abort Calibration

This command aborts the calibration procedure.
Request

Data

Bytes:

None

Command Specific Response Data Bytes: None