PART 2 Electrical Connection

WARNING!

Ensure that the power supply is disconnected before proceeding. Verify that the power supply matches the ratings
found on the appliance data label before proceeding. The complete appliance must be properly grounded at all
times when electrical power is applied. Do not ground the appliance with the neutral (white) house supply wire. A
separate ground wire must be utilized. Failure to complete electrical connections properly may result in damaged
or non-functional systems. Follow instructions carefully to ensure proper installation.

It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this
appliance. The electrical installation, including minimum supply wire size, must comply with the National
Electric Code ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this
standard may be obtained from:

National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471

INSTRUCTIONS:

A 15 to 20 amp electrical service is recommended for proper electrical supply. Always observe local building
codes. Always use a dedicated circuit. The Air-O

®

hood is supplied with a 5.0 amp variable speed fan control.

Wire connections: (See Diagram Below)

There are 3 wires on the front panel that require connection.

BLACK

120 VAC from electrical panel (usually black)

WHITE

Neutral from electrical panel (white)

GREEN

Ground from electrical panel (usually green)

CAUTION:

The neutral wire (white) must only be connected to the white neutral wire coming in from the electrical panel.

Hood

BLK

WHT

GRN

House Electrical

Panel

Green

White

(N)

120V Black (L)