Terminal Block Designation

[For authorized sevice techinician use only]

B. PAWS Control Panel

TB-1

1-Line Hot

2-Line Neutral

Incoming Power Supply 120vac, 15 amps, 60 Hz

3-Mech. Ground

TB-2

1-Switched Hot

2-Neutral

Wash Solenoid #1, 120vac, 1.5 amps max

3-Switched Hot

4-Neutral

Wash Solenoid #2, 120vac, 1.5amps max

5-Switched Hot

6-Neutral

Wash Solenoid #3, 120vac, 1.5amps max

TB-3

1-Switched Hot

2-Neutral

Wash Solenoid #4 120vac, 1.5amps max

3-Switched Hot

4-Neutral

Wash Solenoid #5 120vac, 1.5amps max

5-Switched Hot

6-Neutral

Wash Solenoid #6 120vac, 1.5amps max

TB-4

1-Switched Hot

2-Neutral

Wash Solenoid #7 120vac, 1.5amps max

3-Switched Hot

4-Neutral

Wash Solenoid #8 120vac, 1.5amps max

TB-5

1-Switched Hot

2-Neutral

Detergent Pump, 120vac, 1.5apms max

3-Switched Hot

4-Neutral

PAWS Alarm Horn, 120vac, 1.5amps max

5-Switched Hot

6-Neutral

Fan Contractor, 120vac, 1.5amps max

TB-6

1-Switched Hot

2-Neutral

Spare Output [PAW] 120vac 1.5amps max

*3-Switched Hot

*4-Neutral

Spare Output [MAF II] 120vac, 1.5amps max

5-Neutral

Auxillary

6-Hot

Power Tap

120vac, 120amps max

TB-7

*1-NC

*2-C

Trouble Dry Contacts [MAF II] 1.5amps @ 28vdc/120vac

*3-NO

*4-NC

*5-C

Trouble Dry Contacts [MAF II] 1.5amps @ 28vdc/120vac

*6-NO

TB-8

*1-NC

*2-C

Fire Dry Contacts [MAF II] 1.5amps @ 28vdc/120vac

*3-NO

*4-NC

*5-C

Fire Dry Contacts [MAF II] 1.5amps @ 28vdc/120vac

*6-NO

TB-9

1-Line Hot

PAWS Supervised

]

2-Switched Hot

Valve Switch

|

3-Line Hot

PAWS Manual

|

120vac, 25 milliamps

4-Switched Hot

Fire Pull Switch

|

5-Line Hot

PAWS Automatic |

6-Switched Hot

Fire Switch

]

TB-10

*1-Line Hot

MAF II Water

]

*2-Switched Hot

Flow Switch

|

*3-Line Hot

MAF II Water

|

12vdc, 25 milliamps

*4-Switched Hot

Pressure Switch

|

*5-Line Hot

MAF II Supervised |

*6-Switched Hot

Valve Switch

]

TB-11

1-Detergent

2-Probe

20vdc, 2 milliamps

*3-Positve

*4-Negative

MAF II Horn, 12vdc, 1.5amps

TB-12

1-Positve

2-Negative

Battery, 12v, 5A Hours

3-Positve

Auxillary

4-Negative

Power Tap

*See “Mist-A-Fire Technical Manual” (fig. 10)