1) Place the condensing units WM-250~650SCU in a properly ventilated

location. If it is not, heat exhausted by the condensing unit will build up and
the cooling system will not operate properly.

2) Condensing unit shall be elevated to avoid possible

flooding and shaded from direct sun. It shall not be
exposed to temperatures higher than 110 °F or lower
than 50 °F.

3) Leave minimum 5 ft clearance for the exhaust side and

leave minimum 1 foot clearance for the ambient air
intake side.

4) Service valve operations

1 - Process & Manometer
2 – Receiver Discharge or Compressor Suction
3 – Liquid Line or Suction Line
4 - Pressure Control
Back Position
: Normal operation, process and manometer port closed
Front Position
: Liquid/suction line connection closed
Middle Position: All ports open for evacuation, charge and manometer


BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 9 ROTALOCK Valve Operation


BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 10 Base Valve Operation