- 20 -

2) Use of the

encapsulated pressure control (if applicable)

Fixed suction pressure setting: Cut in = 32 psig; Cut out = 10 psig

Fig. 12 Fixed Pressure Control

3)

Low ambient condition kit (if applicable)


A.

Use of the condenser fan control

Head pressure setting: Cut in=170 psig; Cut out=120 psig; Differential=50 psig
It closes on rise of pressure. It may need to adjust the setting in the field to avoid
fan short cycle.

Fig. 13 Condenser Fan Cycle Control


B.

Use of the crankcase heater


The crankcase heater is installed around the lower part of the compressor and
shall be turned on all the time. The heater is self-regulated.

6. Piping, Checking and Testing

NOTES: