APPENDIX A

TYPICAL SPECIAL STAINLESS STEEL VENTING

For use with Category II, III, IV appliances

Contact Local Building or Fire Officials About Restrictions and Installation Inspections in your area as well as National codes:

USA -National fuel gas code ANS1-Z223.l
CANADA -CAN\CGA-B 149.1 or .2 Fuel Burning Installation Code

Please refer to appliance manufacturers’ instructions to determine proper sizing and connection of venting system to appliance, including

maximum horizontal length, maximum height, and installation clearances (air spaces). The proper operation of the vent system and

appliance requires parts specified by Z-FLEX with no deletions or substitutions. NOTE: Co-venting with other appliances is prohibited

PARTS LIST

COMPONENT 3” SYSTEM CAT. #

4” SYSTEM CAT. #

COMPONENT 3”

SYSTEM CAT. #

4” SYSTEM CA1~#

10 FOOT PIPE

SVEPWC0310

SVEPWC04I0

ADJUST. FLASHING

SVSADJ03 SYSADJ04

8 FOOT PIPE

SVEPWC0308

SVEPWC0408

REDUCER 4” TO 3”

SVSERWC0403 SVSR0404

5 FOOT PIPE

SVEPWC0305

SVEPWC0405

FLAT FLASHING

SVSSCS03 SVSSCS04

4 FOOT PIPE

SVEPWC0304

SVEPWC0404

LOCKING BAND

SVSLBX03 SVSLBX04

3 FOOT PIPE

SVEPWC0303

SVEPWC0403

FIRESTOP SUPPORT

SVSFSS03

SVSFSS04

2 FOOT PIPE

SVEPWC0302

SVEPWC0402

FTRESTOP SPACER

SVSFSX03

SVSFSX04

1 FOOT PIPE

SVEPWC0301

SVEPWC0401

TERMINATION TEE

SVSTTX03 SVSTTX04

6 INCH PIPE

SVEPWC03.5

SVEPWCO4.5

TERMINATION BOX

SVSRTX03 SVSRTX04

90

0

ELBOW SVEEWC0390

SVEEWC0490 RAIN CAP

SVSRCX03 SVSRCX04

45 ELBOW

SVEEWC0345

SVEEWC0345

TOP SUPPORT

SVSLSX03

SVSLSX04

HORJZ. DRAIN TEE

SVEDWC03

SVEDWC04

STORM COLLAR

SVSSCX03

SVSSCX04

VERTICAL DRAIN TEE

SVEVWC03

SVEVWC04

Z-VENT SEALANT

GE106X

WALL THIMBLE

SVSWTX03

SVSWTX04

WM TERM COUPLING

SVSTPX03

WM GV STARTER

SVEWMG03

AMETEK FAN CONN.

SVSACA03

DRAIN TUBE KIT

SVEDTK

WM CGI STARTER

SVEWMFA03

Z-FLEX recommends that the installation be performed by an experienced professional who works with venting systems on a-regular

basis. These instructions are intended as a guide to assist a professional installer.

When the Z-VENT system is installed, the following should be observed:

1.

A venting system that exits the structure through a sidewall or the like, shall terminate not less than 12 inches (254 mm) above the ground

(see illustration # 2, page 4).

2.

The termination of a system shall be located above the snow line in geographical areas where snow accumulates. The termination area

should be kept clear of snow and ice at all times.

3.

The vent shall not terminate less than 7 ft. (2.13 m) above a paved sidewalk or driveway.

4.

The termination shall be 6 ft. (1.8 m) or more from the combustion air intake of any appliance.

5.

The system shall terminate more than 3 ft. (.91 m ) from any other building opening, gas utility meter, service regulator or the like.

6.

Exterior mounted venting systems should be enclosed below the roof line with a chase to limit condensation and protect against

mechanical failure.

NOTES:

A.

The Z-FLEX SPECIAL STAINLESS VENT SYSTEM is for use only with appliances having a positive vent pressure of 3” of water column

or less.

B.

Except for installation in one and two family dwellings, a venting system that extends through any zone above that on which the connected

appliance is located shall be provided with an enclosure having a fire resistance rating equal to or greater than that of the floor or roof

assemblies through which it passes

C.

Do not place any type of insulation in any required air spaces surrounding the venting system.

D.

A termination must be used on all installations to assure proper operation and to prevent debris from entering the venting system.