Table 6-1 . serial commands, Pre l iminar y – Vidikron PLASMAVIEW VP-6500VHDA User Manual

Page 68

Advertising
background image

Serial Communications

56

Vidikron PlasmaView VHD Installation/Operation Manual

PRE

L

IMINAR

Y

Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid
parameter ranges, or “NA” for commands that take no parameters.

When you enter a valid command, the VHD Controller executes it and acknowledges it with a
plus sign on the command line (+ >). When you enter an invalid command – one that is
misspelled or followed by values outside the valid range for that command – the VHD
Controller ignores it and returns a minus sign (- >).

Table 6-1. Serial Commands

Command

Parameter

(min/max)

Value

Stored?

Description

Power On/Off Commands

OFF

NA

NA

Turns system off

ON

NA

NA

Turns system on

POWER

0/1

NA

Turns system on or off (toggles on/off state)

POWER?

NA

NA

Returns power status

Input Selection Commands

COMPONENT

NA

YES

Selects the Component input

COMPOSITE

NA

YES

Selects the Composite video input

HDMI1

NA

YES

Selects the HDMI 1 input

HDMI2

NA

YES

Selects the HDMI 2 input

HD1

NA

YES

Selects the RGB/HD 1 input

HD2

NA

YES

Selects the RGB/HD 2 input

INPUT?

NA

NA

Returns active input

SVIDEO1

NA

YES

Selects the S-Video 1 input

SVIDEO2

NA

YES

Selects the S-Video 2 input

Aspect Ratio Commands (not available on HDMI 1 or HDMI 2 inputs)

16:9

NA

YES

Selects the 16:9 aspect ratio

ASPECT?

NA

NA

Returns current aspect ratio

CINEMA

NA

YES

Selects the Cinema aspect ratio

LETTERBOX

NA

YES

Selects the Letterbox aspect ratio

4:3

NA

YES

Selects the 4:3 aspect ratio

INTELLIWIDE

NA

YES

Selects the IntelliWide aspect ratio

Advertising