Installation – Vanguard VMH26TNC User Manual

Page 15

Advertising
background image

www.desatech.com

113111-01H

15

InsTallaTIon

Continued

Figure 18 - Installing Switch Plate to

Valve Cover Shield

Switch
Plate

Screw

Valve Cover
Shield

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring

harness to electrical supply

following all local codes. Electri-

cian must provide a clamp on the

box cover to secure the wiring.

Wiring should be routed through

the bushing in the hole on the

outer casing of heater.

Follow instructions for Removing Valve
Cover Shield,
page 13. Continue installation
as follows:
1. Install a snap bushing found in hardware

kit into one of the holes found on rear of
valve cover shield. The other hole is for a
strain relief clamp (not supplied) to secure
incoming electrical supply.

2. Follow steps 2 through 6 in Installing

Blower Assembly, page 14. Also remove
black wire from middle switch terminal 2.

3. Remove black plastic strain relief and power

cord from switch plate. The power cord
supplied will not be used in built-in installa-
tions. Pop in the plastic snap bushing found
in hardware kit into the hole left by supply
cord/strain relief.

4. A licensed electrician must follow the wir-

ing diagram to connect incoming electri-
cal supply to fan kit wiring harness (see
Figure 19).

5. Plug power cord to the outlet receptacle

(not provided) as shown in Figure 18.
Wind the extra power cord and tie it up
with the plastic wire strap (see Figure
20, page 16). Set the power cord bundle
between the burner bracket and outer
casing, away from the burner.

6. Reinstall valve cover shield.
7. Test to make sure the blower is working

properly.

8. Reinstall upper louver assembly and hood

if previously removed, (see Figure 15,
page 13). Close lower louver door.

Red

Red

Fan Switch (Auto/Of

f/On)

Blue

Blue

Thermostat

Switch (N.O.)

Green

White

Green

White

On

11

0/1

15

V

.A.C.

Blower Motor

Black

Of

f

1

2

3

Auto

Figure 19 - Wiring Diagram For Blower

Accessory Built-In Installation

Note: When switch is in AUTO position,
fan will start after heater has run for a
few moments. Fan will continue to run
for several moments after heater has
been turned off. When switch is in the
ON position, fan will run until turned to
OFF. Reinstall upper louver assembly and
hood if previously removed, (see Figure
15, page 13). Close lower louver door.

Advertising