Operation – Vanguard VMH26TNC User Manual

Page 20

Advertising
background image

www.desatech.com

113111-01H

20

Note: If pilot does not stay lit, refer to
Troubleshooting, page 24. Also contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure,
page 21.

7. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob.

Note: If pilot goes out, repeat steps 3
through 7. This fireplace has a safety
interlock system. Wait one (1) minute
before lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

9. To shut off burner only and leave pilot lit,

turn countrol knob clockwise

to

PILOT position.

oPeRaTIon

Continued

Ignitor Button

Figure 28 - Control Knob In The OFF

Position

Control Knob

Thermocouple

Pilot Burner

Figure 29 - Pilot (Propane/LP Shown)

Ignitor Electrode

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the fireplace

screen in place. Make sure fire-

place screen is installed before

running fireplace.

NOTICE: During initial operation

of new fireplace, burning logs

will give off a paper-burning

smell. Orange flame will also be

present. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

1. STOP! Read the safety information start-

ing, page 19.

2. Make sure equipment shutoff valve is

fully open.

3. Turn control knob clockwise

to OFF

position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in safety information, page 19. If you don’t
smell gas, go to next step.

5. Turn control knob counterclockwise

to PILOT position. Press in control knob for
five (5) seconds (see Figure 28).

Note: You may be running this fireplace
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

6. With control knob pressed in, push down

and release ignitor button. This will light
pilot. Pilot is attached to front of burner. If
needed, keep pressing ignitor button until
pilot lights.

Advertising
This manual is related to the following products: