Wiring

12

Installation and Operations Manual

3.1.1

Power

To connect DC or AC power to the 8620, connect the power wires to the appropriate terminals

supplied with the 8620 DET.

Note Before connecting power wires to the 8620 DET, ensure that the power is switched

off and that the 8620 DET is correctly grounded.

AC Wiring

To connect the AC wiring, perform the following steps:

1. Connect the hot wire to the fuse holder as shown in Figure 3-1 on page 10.
2. Connect the neutral wire to the black terminal as shown in Figure 3-1 on page 10.
3. Connect the ground wire to the green/yellow terminal.

DC Wiring

To connect the DC wiring, perform the following steps:

1. Connect the 20 - 48 VDC positive wire to the bottom of the fuse holder as shown in

Figure 3-2 on page 11.

2. Connect the negative wire to black terminal as shown in Figure 3-2 on page 11.
3. Connect the ground wire to the green/yellow terminal.

3.1.2

Communications

RS-485 is the default setting used for Com 2 as shown in Figure 3-1 on page 10.

RS-422 and RS-485 Wiring — Com 2

Note Com 1, Com 3, and Com 4 are all standard RS-232 Ports. All communications ports

are standard DB-9 male connectors. Com 2 also supports RS-232 if properly con-

figured.

DB-9 Connector on I/O Bracket

Pin

Pin Name

Signal Type

1

422-RXD-

IN

2

422-RXD+

IN

3

485-422-TXD+

OUT

4

485-422-TXD-

OUT

Table 3-1:

4-Pin Connectors for RS-422 and RS-485 Communication Protocols