5 8620 det voltage monitor, 6 resetting the 8620 det – Varec Driver Entry Terminal 8620 User Manual

Page 32

Advertising
background image

Maintenance and Troubleshooting

24

Installation and Operations Manual

5.2.5 8620 DET Voltage Monitor

The voltage monitor monitors the input voltage and detects whether the voltage is low or below

an acceptable level (for DC units only). The voltage monitor LED indicates the different states of

the input voltage (see Table 5-5 below).

For AC units, the LED indicates that power is supplied to the unit.

Figures 5-3 shows the location of the 8620 DET voltage monitor LED.

Figure 5-3: 8620 DET Voltage Monitor LED and Reset Button Locations

Table 5-5 lists the input voltage and the state of the LED for monitoring the voltage.

Note The LED remains Red once the supplied power to the 8620 DET becomes

unacceptable. Contact your Varec representative for more information when the LED is RED.

5.2.6

Resetting the 8620 DET

Note The reset button resets the CPU of 8620 DET, but does not reset the voltage monitor.

To reset the 8620 DET, toggle the reset button shown in Figures 5-3 above.

Input Voltage

LED

Above 23 VDC

Solid Green

Approximately 23 VDC - 19 VDC Flashes Green
Below 19 VDC

Red (The LED remains Red even if good power is restored).

Contact Varec for more information.

Table 5-5:

Input Voltage and LED State

8620 Voltage

Monitor LED

8620 DET