5.9. Filter Settings

Perform Filter (HPF/LPF) settings of Input / Output channels. 9000Series Amplifier
responds with the same data as that received.

Note: Command cannot be received during power off.

A2H, 04H, <Channel Attribute>, <Channel Number>, <HPF/LPF>, <Value>

<Channel Attribute>

00H: Input channel
01H: Output channel

<Channel Number>

00H - 07H (Input channel 1 - 8)
00H - 07H (Output channel 1 - 8)

<HPF/LPF>

00H: High Pass Filter

01H: Low Pass Filter

<Frequency Value>

HIGH PASS FILTER

TABLE – 00H



















LOW PASS FILTER

TABLE – 01H















Example: Setting the Input Channel 3’s High Pass Filter to 31.5 Hz.

A2H, 04H, 00H, 02H, 00H, 03H

Value

HEX

DEC

HPF (Hz)

00H 0 OFF
01H 1

20

02H 2

25

03H 3 31.5
04H 4

40

05H 5

50

06H 6

63

07H 7

80

08H 8

100

09H 9

125

0AH 10

160

0BH 11

200

0CH 12

250

0DH 13

315

0EH 14

400

Value

HEX

DEC

LPF (Hz)

00H 0

4k

01H 1

5k

02H 2 6.3k
03H 3

8k

04H 4

10k

05H 5 12.5k
06H 6

16k

07H 7

20k

08H 8 OFF

Advertising