6 serial communications, 1 rs-232 connection and port configuration, 2 serial command syntax – Vidikron VL-37 User Manual

Page 57: Table 6-1 . serial commands, Serial communications, Rs-232 connection and port configuration, Serial command syntax

Advertising
background image

Vidikron VL-37 Owner’s Operating Manual

47

6.1
RS-232 Connection and
Port Configuration

To interface the DView with a home theater automation/control system or a PC running
terminal emulation software, connect it to your control system or PC as shown in Figure 3-7.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit
and no flow control. Set the baud rate to match that of the DView RS-232 port; the default
baud rate is 115200.

6.2
Serial Command Syntax

Table 6-1 lists the RS-232 command set. All commands are in ASCII format. A carriage return
is not required after a command.

When you send a valid command, the DView executes it and acknowledges it with a
right-bracket character (

]

) followed by the four-digit numeric code you sent; for example,

]0002

. When you send an invalid command, the DView ignores it and returns

-N/A

instead

of the four-digit code.

6

Serial Communications

Table 6-1. Serial Commands

Command

Description

[

+

S3A

+

000#

Set audio volume to ### (=000-100)

Example: [ S3A000075 sets volume to 75

[

+

+3A

Audio volume up

[

+

- 3A

Audio volume down

[

+

S4A

+

000#

Main input selection

1=Input1

2=Input2

3=Input3

4=Input4

5=DVI

6=RGB

Example: [ S4A0006 selects RGB

[

+

S4E

+

000#

Aspect ratio selection

0=Standard (4x3)

1=IntelliWide

2=Letterbox

3=Anamorphic

Example: [ S4E0002 selects Letterbox

[

+

S4F

+

0101

Select Composite Video for Input1

+

0102

Select S-Video for Input1

+

0201

Select Composite Video for Input2

+

0202

Select S-Video for Input2

+

0301

Select Composite Video for Input3

+

0303

Select Component Video for Input3

Advertising