Service procedures – Vanguard Heating GVB35P User Manual

Page 31

Advertising
background image

31

100354

SERVICE

PROCEDURES

Continued

Removing Burner

1. Shut off gas supply to

heater.

2. Remove lower front

access panel on heater.

3. Disconnect burner tube

from orifice holder (see
Figure 23).

4. Remove orifice holder

from burner (see Figure
23).

5. Remove pilot burner

bracket nuts and remove
pilot assembly (see Figure
23).

6. Move burner to the right

for clearance. Rotate
burner 90° and remove
burner through lower front
access opening.

7. To reinstall, reverse above

steps. Turn on gas to
heater and check for gas
leaks. Apply a mixture of
liquid soap and water to
all joints. Bubbles form-
ing show a leak. Correct
all leaks at once.

8. Replace lower front

access panel.

Figure 23 - Removing Burner Tube, Orifice Holder,

and Pilot Burner Assembly (35,000 BTU/Hr Burner Shown)

Burner
Tube

Orifice
Holder

Pilot Burner
Bracket Nut

Burner

Pilot Burner
Assembly

Continued

Advertising
This manual is related to the following products: