100354

INSTALLING

HEATER

Continued

LOCATING HEATER

WARNING

Never install the heater

• in a mobile home or a recreational vehicle.
• where curtains, furniture, clothing, or other flam-

mable objects are less than 48 inches from the front,
53 inches from the top, 12 inches from the right side
and 6 inches from the left side and back of heater.

• directly on carpeting, tile, or other combustible

materials other than wood flooring. Place heater on
metal or wood panel extending the full width and
depth of heater.

• as a fireplace insert.
• in high traffic areas.
• in windy or drafty areas.

For convenience and efficiency, install heater

• where there is easy access for operation, inspection, and service.
• in coldest part of room.
• near an electrical outlet if you are planning to add blower to heater. See

Accessories, page 35 for blower.

WARNING

Maintain the minimum clearances shown in Figure 3,
below. If you can, provide greater clearances.

53"

Minimum

CEILING

Left
Side

6"

Minimum

Right
Side

48" Minimum from

Front of Heater

6" Minimum

from Back

12"

Minimum

Figure 3 - Heater Clearances

CAUTION

If you install the heater in a home garage

• heater pilot and burner must be at least 18 inches

above floor

• locate heater where moving vehicle will not hit it.

Continued