Local codes unpacking, Product features, Installing heater – Vanguard Heating GVB35P User Manual

Page 6: Notice, Warning

Advertising
background image

6

100354

Install and use heater with care. Follow all local codes. In the absence of local
codes, use the latest edition of the following:

• National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 *
• National Electrical Code ANSI/NFPA 70 *
• National Standard of Canada CAN1-B149 **

*Available from: American National Standards Institute, Inc., 1430 Broadway
New York, NY 10018; National Fire Protection Association, Inc., Batterymarch
Park, Quincy, MA 02269.

**Available from: Standards Council of Canada, 350 Sparks Street, Ottawa,
Ontario, K1R 7S8.

LOCAL CODES

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged, promptly inform

dealer where you bought heater.

PRODUCT

FEATURES

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries, or other
sources to light heater.

Thermostatic Heat Control

This heater has a thermostat sensing bulb and a control valve. This results in the
greatest heating comfort. This can also result in lower gas bills.

NOTICE

This heater must be electrically grounded if equipped with
blower. Follow all local codes. In the absence of local
codes, follow the National Electric Code, ANSI/NFPA 70
(U.S.) or Canadian Electrical Code CSA C22.1 (Canada).

INSTALLING

HEATER

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane, do not install heater. Call
dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have all items below.

• external regulator (supplied by

installer, see page 10)

• piping (check local codes)
• sealant (resistant to propane gas)
• manual shutoff valve *
• ground joint union

• test gauge connection * (see

Figure 7, page 12)

• sediment trap
• tee joint
• pipe wrench
• venting materials

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an
acceptable alternative to test gauge connection. Purchase the optional A.G.A.
design-certified manual shutoff valve from your dealer. See Accessories, page 35.

WARNING

A qualified service person must install heater and venting
system. Have them inspect heater before use and at least
annually. Follow all local codes.

Advertising