Troubleshooting – Vanguard VE36L User Manual

Page 13

Advertising
background image

www.desatech.com

115121-01B

13

TROUBLESHOOTINg

Note: Before troubleshooting system, make sure power to circuit from breaker or fuse panel
is turned ON.
The three most common causes of a malfunctioning electric fireplace are:
1. Tripped circuit breaker or blown fuse.
2. Loose or burned out light bulb.
3. Obstructed or clogged fan blower.

POSSIBLE CAUSE

1. No power to fireplace

2. Defective switch lamp

3. Defective wiring

1. Tangled or loose flame

pennants

2. Obstructed or clogged fan

blower

3. Damaged or dislodged fan

blower wheel

1. Burned out or loose light

bulb

2. Broken lamp fixture

3. Loose or missing reflective

ribbons

1. Obstructed heater blower

2. Burned out heat element

or blower fan

3. Defective heater switch or

wiring

REMEDY

1. Check circuit breaker or fuse

2. Replace defective switch.

See Servicing Control Pan-

el, page 16

3. Check connections from

main power harnesses to

terminals on control panel.

See Servicing Control Pan-

el, page 16

1. Inspect flame pennants. Un-

tangle or replace if neces-

sary. See Servicing Flame

Pennants, page 18

2. Check fan blower for de-

bris. Vacuum areas around

blower wheel and remove

any obstructions. See Main-

taining Motors, page 15

3. Remove and inspect fan

blower housing See Servic-

ing Fan Blower, page 18

1. Inspect light bulbs; tighten

or replace light bulbs as

necessary. See Replacing

Light Bulbs, page 15

2. Remove and replace broken

lamp fixture. See Replacing

Lamp Fixtures, page 20

3. Inspect reflective ribbons.

Reattach or replace as nec-

essary. See Replacing Re-

flective Ribbons, page 21

1. Clear heater fan of debris

or blockage; vacuum area

around blower intake and

remove any obstructions

in the discharge area. See

Maintaining Motors, page 15

2. Remov and replace blower

heater assembly. To access

and remove see Optional

Heater Accessory, page

10

3. Inspect wiring connections

from switch to blower. Re-

place switch if defective.

See Servicing Control Pan-

el, page 16

OBSERvED PROBLEM

No operation or indicator light

at power/heater switch

Poor flame motion; flame pat-

tern is sporadic or uneven in

viewing area

Dull flame appearance or inac-

tive ember bed effect

No heat or intermittent heat

output. (If equipped with a

heater)

Advertising
This manual is related to the following products: