Maintenance – Vanguard VE36L User Manual

Page 15

Advertising
background image

www.desatech.com

115121-01B

15

MAINTENANCE

WARNING: Disconnect

power before attempting any

maintenance or cleaning to re-

duce the risk of fire, electrical

shock or personal injury.

WARNING: Any electrical

repairs or rewiring of this unit

should be carried out by a

licensed electrician in accor-

dance with national and local

codes.

WARNING: Do not exceed

60 watts per bulb when replac-

ing bulbs. Use of higher-rated

bulbs may result in a fire, caus-

ing property damage, personal

injury, or loss of life.

REPLACING LIGHT BULBS

There are (3) colored lamps rated at 120V,
60 Watts, for use in a medium sized socket.
These bulbs are located under the log bed
and can be replaced as follows:
1. If you are unsure which bulb needs

replacement, defective bulbs may be
visually located as any of 3 bulbs colored
- Red, Yellow and Orange starting from
the left (see Figure 12, page 7). Defective
bulbs can be replaced individually or for
convenience you may want to replace all
bulbs at the same time; even if only one
is defective.

2. Disconnect power to unit at main breaker

or fuse panel.

3. Lift log bed off hearth base to gain access

to lamp fixtures. Log bed is attached with
contact magnets only.

4. Remove each defective bulb from its

socket and replace with appropriate color
and size bulb.

Note: Be careful not to tear or damage reflec-
tive ribbons. If they have come loose, they
can be easily reattached or replaced at the
support brackets. See Replacing Reflective
Ribbons
, page 21.

5. Return power to circuit and turn main power

switch and lamp power on to check opera-
tion of bulbs before replacing log set.

6. If all bulbs are working properly, replace

the log bed over the center opening in
between rear screen and front grate.

CAUTION: Make sure power

is turned off at supply prior to

disassembling this unit.

MAINTAINING MOTORS

Motors used on fan and heater assembly
are permanently lubricated and do not
require lubrication. Annual cleaning and/or
vacuuming around heater and fan unit is
recommended.

REMOvING/REPLACING CONTROL
DOOR

The upper control door may be removed for
service or replacement when necessary:
1. Open upper control door (see Figure 13,

page 7).

2. Remove 4 Phillips screws from deflector

shield. Angle deflector shield out of open-
ing (see Figure 29).

3. Remove 4 Phillips screws from magnet

assemblies.

4. Lift up on inner control door and push

in each end until pivot pins are free of
notches located on each side of access
opening (see Figure 29).

Figure 29 - Removing/Replacing Control

Door

Deflector
Shield

Control
Door

Magnet
Assembly

Push
Door Up
and
Back

Angle
Door and
Slide
Out of
Housing.

Advertising