SERvICING FAN BLOWER

To remove fan blower:
1. Follow instructions under Accessing Imag-

ing Unit, page 17.

2. Remove 3 light bulbs from lamp fixtures

(see Replacing Light Bulbs, page 15).

3. Disconnect two 1/4" blade connectors

from posts on motor unit.

4. Remove 4 hex nuts and washers located

on blower mounts at base of cabinet (see
Figure 37).

5. Lift entire fan assembly off of mounts and

tilt out of unit.

6. Remove screws with washers and hex

nuts from fan housing.

7. Mount new fan to blower mount in reverse

order.

8. Slide blower assembly with spacers over

mounting lugs and replace washer and
nut at each lug. Do not over tighten.

9. Attach blade connectors to posts on

motor mount. Note: Wire connectors for
fan motor are non-polarized and may be
connected to either terminal for proper
operation.

SERvICING FLAME PENNANTS

If flame pennants should become tangled or
detached reattach or replace.
1. Locate affected flame pennant. Slip hem

at base of flame pennant over proper
hanger bracket position. See Figure 38,
page 19, for proper location.

2. Pull flame cord up to proper hook location,

use a slip knot to adjust cord length and
attach cord to hook.

3. Tie another knot over slip knot and trim

away excess cord.

MAINTENANCE

Continued

Figure 36 - Removing Base Cover

Base
Cover

Figure 37 - Removing Fan Assembly (Shown without Firebox for Clarity)

Washer

Hex Nut

Fan Assembly

Blower
Mount
(1 of 4)

Washer Hex

Nut

Screw

Spacer

Posts for Blade
Connectors

Advertising