Clearance Dimensions

(Wood/Composite Overlay)

11

Clearance Dimensions

(Proximity to Cabinets)

10

• This range may be installed directly

adjacent to existing 36” (91.4 cm) high
base cabinets.

IMPORTANT: The side trim MUST be
3/8” (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.

• The range CANNOT be installed

directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above 36”
(91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side
clearance from the range to such
combustible surfaces above the
36” (91.4 cm) counter height.

• Within the 6” (15.2 cm) side

clearance to combustible vertical
surfaces above 36” (91.4 cm), the
maximum wall cabinet depth
must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm)
side clearance must be 18”
(45.7 cm) above the 36”
(91.4 cm) high countertop.

• Wall cabinets above the range must be a

minimum of 42” (106.7 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.

The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information.
These dimensions provide for safe and
efficient operation of the hood.

66”

min

.

(167

.6 c

m)

to

72”

max

.

(182

.9 c

m)

30

(76

.2

cm

)

6”

(15

.2 c

m)

Woo

d/C

om

posit

e

Ove

rlay

30”

min

.

(76.2

cm

)

to

36”

max

.

(91.4

cm

)

66”

min

.

(167

.6 c

m)

to

72”

max

.

(182

.9 c

m)

24

(61

.0

cm

)

or

27

(38

.6

cm

)

Woo

d/C

om

posit

e

Ove

rlay

0”

(

0 c

m)

30”

min

.

(76.2

cm

)

to

36”

max

.

(91.4

cm

)

Wall Installation

Island Installation

Note: Minimum clearance for back wall
is 0” with backguard or high-shelf. See
Standoff Bracket Removal section to
allow 0” clearance.

CAUTION

Burn hazard

To avoid risk of personal injury;

the use of cabinets for storage

above the appliance may result

in a potential burn hazard. Combustible

items may ignite, metallic items may

become hot and cause burns. If a cabinet

storage is to be provided the risk can be

reduced by installing a rangehood that

projects horizontally a minimum 5”

(12.7 cm) beyond the bottom of cabinets.

Range

Width

“A”

Dimension

30”

30” (76.2 cm)

36”

36” (91.4 cm)

48”

48” (121.9 cm)

60”

60-1/4” (153.0 cm)

Note: If a range hood is installed, wall cabinets above
the range have a different minimum clearance height.

Note: Minimum clearance for back wall is 0” with
backguard or high-shelf.

Important: This range comes standard
with an Island Trim. There must be a
minimum of 6” (15.2 cm) clearance from
rear of range to a combustible wall.
Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.