Figure 15 - Attaching Fireplace to Wall

Studs

Nailing
Flanges

Nails or
Wood
Screws

Mantel Clearances for Built-In Installation
If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening.
If your installation does not meet the below mini-

mum clearances, you must:
• raise the mantel to an acceptable height,
OR
• remove the mantel.

Figure 16 - Minimum Mantel Clearances

for Built-In Installation

Mantel Shelf

13"

16"

19"

21"

2

1

/

2

"

6"

8"

10"

Minimum Non-
Combustible
Material

Note: All Vertical
measurements are
from top of fireplace
opening to bottom
of mantel shelf.

INSTALLING GAS PIPING TO
FIREPLACE LOCATION

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: Never connect

propane/LP fireplace directly

to the propane/LP supply. This

heater requires an external regu-

lator (not supplied). Install the

external regulator between the

heater and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

2. If using blower, install and properly ground

GA3555, three-prong 120 volt electrical outlet,

in fireplace. Follow instructions included in kit.

3. Install gas piping into fireplace location. This

installation includes an approved flexible gas

line (if allowed by local codes) after the equip-

ment shutoff valve. The flexible gas line must

be the last item installed on the gas piping. See

Installing Gas Piping to Fireplace Location,

column 2.

4. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

5. Plug electrical cord into electrical outlet

installed in step 2.

6. Carefully insert fireplace into rough opening.
7. Attach flexible gas line to gas supply. See Con-

necting Fireplace to Gas Supply,

page 14.

8. Attach fireplace to wall studs using nails or

wood screws through holes in nailing flange

(see Figure 15).

9. Check all gas connections for leaks. See

Checking Gas Connections

, page 15.

10. Install trim after final finishing and/or painting

of wall (see Figure 7, page 9).