Troubleshooting – Vanguard Heating VSGF-28PTE User Manual

Page 23

Advertising
background image

www.desatech.com

113135-01C

23

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Turning control knob to HI

position when burners are

cold

2. Air in gas line

3. Air passageways on fireplace

blocked

4. Dirty or partially clogged

burner orifice(s)

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Improper log placement

2. Drafts or other air currents

affecting flame pattern

3. Air holes at burner inlet

blocked

4. Burner flame holes blocked

1. Metal expanding while heat-

ing or contracting while

cooling

REMEDY

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burners until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum installa-

tion clearances (see pages 10

through 12)

4. Clean burners (see Cleaning

and Maintenance, page 20)

or replace burner orifice(s)

1. Turn heater off when using

furniture polish, wax, carpet

cleaners, or similar products

1. Properly locate logs (see In-

stalling Logs, page 16)

2. Eliminate source of drafts

around heater

3. Clean out air holes at burner

inlet. Periodically repeat as

needed

4. Remove blockage

1. This is common with most

fireplaces. If noise is exces-

sive, contact qualified service

person

OBSERVED PROBLEM

Fireplace produces a whistling

noise when burners are lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Dark residue on logs or inside

of fireplace

Note:

After removing all causes

of residue deposits, completely

clean fireplace and appliance

of all residue before reusing

appliance

Fireplace produces a clicking/

ticking noise just after burners

are lit or shut off

Advertising