Vivotek VS2403 User Manual

Page 68

Advertising
background image

- 67 -

www.vivotek.com

<auto>

Using NTP to sync date/time
automatically

ntp
(r/w)

<domain name or IP
address>

NTP server
<skip to invoke default server>

timezone
(r/w)

-12 ~ 12

time zone, 8 means GMT +8:00
<8>

updateinterval
(r/w)

0 ~ 2592000

0 to Disable automatic time adjustment,
otherwise, it means the seconds
between NTP automatic update interval.
<0>

serialnumber
(r)

<mac

address>

12 characters mac address without
hyphen connected

firmwareversion
(r)

<text string shorter
than 39 characters>

The version of firmware, including
model, company, and version number

0

Restore the system parameters to
default value.

restore
(w)

Positive

integer

Restore the system parameters to
default value and restart the server after
<value> seconds.

0 ~ 65535

Restart the server after <value>
seconds.

reset
(w)

-1

Not restart the server.

H – NC connected with COMMON

do<1~4>
(w)

<state>

L – NO connected with COMMON
H – NC connected with COMMON

di<1~4>
(r)

<state>

L – NO connected with COMMON

supportscriptversion
(r)

<text string shorter
than 10 characters>

The version of supported script/webpage

scriptversion

<text string shorter
than 10 characters >

The maximum version of currently
installed script/webpage

language

<text string shorter
than 16 characters>

The webpage language

webpageversion <text string shorter

than 39 characters>

The version of webpage

0

Turn on the IR control

enableir(r/w)

1

Turn off the IR control

Advertising