10

3. Log Data Request

The data string below requests Log Data from Exchange #1 (only). After the Log Data Request has been
sent, the Log Data string will be sent to the PC in the format shown on the next page (Example 4. Log
Data Format).

Field Name

Length
(Bytes)

Value

Description

Direction

DLE

1

10H

Delimiter

ENQ

1

05H

Enquiry

VS-900MF to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900MF

DLE

1

10H

Delimiter

STX

1

02H

Start Of Text

Log Data

1

4FH

Log Data Request

All Exchanges

2

30H 30H

ON/OFF Status

16

31H 30H 30H 30H 30H 30H
30H 30H 30H 30H 30H 30H

30H 30H 30H 30H

Exchange #1 Log Data
31H = “On" 30H=”Off”

DLE

1

10H

Delimiter

ETX

1

03H

End Of Text

BCC

1

5DH

Block Check Character*

VS-900MF to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900MF

DLE

1

10H

Delimiter

EOT

1

04H

End of Transmission

VS-900MF to PC

4. Log Data Format

This example illustrates five data strings that occur when “Normal” priority Sub-station #105 initiates a call
to Master Station #200 at 16:37:23.

Call From Normal Sub-station

Field Name

Length
(Bytes)

Value

Description

Direction

DLE

1

10H

Delimiter

ENQ

1

05H

Enquiry

VS-900 to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900

DLE

1

10H

Delimiter

STX

1

02H

Start Of Text

Log Data

1

6FH

Log Data

Exchange #

2

30H 31H

Exchange # “01”

Time (HH:MM:SS)

6

31H 36H 33H 37H 32H 33H Time: “16:37:23"

Line #1

6

31H 30H 35H 20H 20H 20H Calling Station # “105”

Line #2

6

32H 30H 30H 20H 20H 20H Called Station # “200”

Line #3

6

20H 20H 20H 20H 20H 20H Not Used (Blank)

Line #4

6

20H 20H 20H 20H 20H 20H Not Used (Blank)

Status #

2

30H 31H

“01” (Call from Normal
Sub-station)

DLE

1

10H

Delimiter

ETX

1

03H

End Of Text

BCC

1

78H

Block Check Character

VS-900MF to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900

DLE

1

10H

Delimiter

EOT

1

04H

End of Transmission

VS-900MF to PC