TOA VS-900 Programmer’s Guide

8

Examples

1. Remote Dialing

The data sequence below will remote dial Master Station #1 in Exchange #1 to dial Sub-Station #105 and
initiate communication. The “CC” (Clear) is included to terminate any current Master Station functions.
Note: The total Dialing Contents must be 32 bytes.

Field Name

Length
(Bytes)

Value

Description

Direction

DLE

1

10H

Delimiter

ENQ

1

05H

Enquiry

PC to VS-900MF

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

VS-900MF to PC

DLE

1

10H

Delimiter

STX

1

02H

Start Of Text

Remote Dial

1

4EH

Remote Dialing
Command

Exchange #

2

30H 31H

EXCHANGE # "01"

Master Station #

1

31H

MASTER # "1"

Dialing Contents 32 Bytes

43H 43H 31H 30H 35H

20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H

20H 20H 20H

"CC105"

DLE

1

10H

Delimiter

ETX

1

03H

End Of Text

BCC

1

79H

Block Check Character

PC to VS-900MF

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

VS-900MF to PC

DLE

1

10H

Delimiter

EOT

1

04H

End of Transmission