TOA VS-900 Programmer’s Guide

12

Start of Normal Conversation

Field Name

Length
(Bytes)

Value

Description

Direction

DLE

1

10H

Delimiter

ENQ

1

05H

Enquiry

VS-900 to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900

DLE

1

10H

Delimiter

STX

1

02H

Start Of Text

Log Data

1

6FH

Log Data

Exchange #

2

30H 31H

Exchange # “01”

Time
(HH:MM:SS)

6

31H 36H 33H 37H 32H

37H

Time: “16:37:27"

Line #1

6

32H 30H 30H 20H 20H

20H

Calling Station # “200”

Line #2

6

31H 30H 35H 20H 20H

20H

Called Station # “105”

Line #3

6

20H 20H 20H 20H 20H

20H

Hold Station # (Blank)

Line #4

6

20H 20H 20H 20H 20H

20H

Not Used (Blank)

Status #

2

31H 30H

“10” (Start of normal
conversation)

DLE

1

10H

Delimiter

ETX

1

03H

End Of Text

BCC

1

74H

Block Check Character

VS-900MF to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900

DLE

1

10H

Delimiter

EOT

1

04H

End of Transmission

VS-900MF to PC

Normal Call Termination

Field Name

Length
(Bytes)

Value

Description

Direction

DLE

1

10H

Delimiter

ENQ

1

05H

Enquiry

VS-900 to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900

DLE

1

10H

Delimiter

STX

1

02H

Start Of Text

Log Data

1

6FH

Log Data

Exchange #

2

30H 31H

Exchange # “01”

Time (HH:MM:SS)

6

31H 36H 33H 37H 32H 38H Time: “16:37:28"

Line #1

6

32H 30H 30H 20H 20H 20H Calling Station # “200”

Line #2

6

31H 30H 35H 20H 20H 20H Called Station # “105”

Line #3

6

20H 20H 20H 20H 20H 20H Not Used (Blank)

Line #4

6

20H 20H 20H 20H 20H 20H Not Used (Blank)

Status #

2

33H 32H

“32” (Normal call
termination)

DLE

1

10H

Delimiter

ETX

1

03H

End Of Text

BCC

1

73H

Block Check Character

VS-900MF to PC

DLE

1

10H

Delimiter

ACK

1

06H

Acknowledge

PC to VS-900

DLE

1

10H

Delimiter

EOT

1

04H

End of Transmission

VS-900MF to PC