General purpose i/o – VXI EX7000 User Manual

Page 21

Advertising
background image

www.vxitech.com

EX7000 Series Basic Operation

21

When enabled as an output, each channel also has the ability to generate a 1 µs pulse upon
command. An example application of this pulse is to use the EX7000 to externally trigger another
piece of test equipment. The specific operation of the pulse depends on the static level
programmed for that channel. When a channel is programmed with a static level of high, the pulse
will be low-going. When a channel is programmed with a static level of low, the pulse will be
high-going. Each pulse generation requires a separate command.

The electrical specifications for the digital I/O port are provided in Table 3-1. Particular note
should be given to the V

INPUT

specification of -0.5 V to 5.5 V. Exceeding that value with an

external voltage source, even through a resistance, could permanently damage the EX7000.

Characteristic

Value

V

INPUT

-0.5 V to 5.5 V

V

IH

2 V min

V

IL

0.8 V max

V

OH

(I

OH

= -32 mA)

2 V min

V

OL

(I

OL

= 64 mA)

0.55 V max


T

ABLE

3-1:

D

IGITAL

I/O

P

ORT

E

LECTRICAL

S

PECIFICATIONS

General Purpose I/O

The EX72SF features an additional 32-bit general purpose TTL I/O port. This is in additional to
the internal 72-channel relay drivers and the 8-bit digital I/O described above. The following are
the pin assignments for the rear-mounted 37-pin D-sub connector:

Pin

Signal

Pin

Signal

1 GND

20

PIO-PORT0

2 PIO-PORT1

21

PIO-PORT2

3 PIO-PORT3

22

PIO-PORT4

4 PIO-PORT5

23

PIO-PORT6

5 PIO-PORT7

24

PIO-PORT8

6 PIO-PORT9

25

PIO-PORT10

7 PIO-PORT11

26

PIO-PORT12

8 PIO-PORT13

27

PIO-PORT14

9 PIO-PORT15

28

GND

10 +5

V

29 GND

11 PIO-PORT16

30 PIO-PORT17

12 PIO-PORT18

31 PIO-PORT19

13 PIO-PORT20

32 PIO-PORT21

14 PIO-PORT22

33 PIO-PORT23

15 PIO-PORT24

34 PIO-PORT25

16 PIO-PORT26

35 PIO-PORT27

17 PIO-PORT28

36 PIO-PORT29

18 PIO-PORT30

37 PIO-PORT31

19 GND

A current limited supply of +5 V is provided on pin 10. An internal, resettable fuse is provided to
protect 200 mA against excessive current flow and short circuits.

Advertising