EX72SF

The EX7SF enclosure , shown in Figure 1-2,can accommodate a large number and various types
of Agilent latching switch modules. The upper six switch mounting locations, designated SW1 to
SW6, are designed for SPDT switches. The lower six switch mounting locations, designated SW7
to SW12, are designed for SP4T, SP6T, and transfer switches.

The following table provides the switch model choices for these sections:

VTI

M

ODEL

D

ESCRIPTION

A

GILENT

M

ODEL

N

UMBER

SPDT (SW 1 – 6)

7202-20

SPDT, 20 GHz

8765B

7202-26

SPDT, 26 GHz

8765C

7202-20T

SPDT, T, 20 GHz

8762B

7202-26T

SPDT, T, 26 GHz

8762C

87202-20T

SPDT, T, EL, 20 GHz

N1810TL - 020

87202-26T

SPDT, T, EL, 26 GHz

N1810TL - 026

SP4T (SW7-12)

7204-20

SP4T, 20 GHz

L7204B

7204-26

SP4T, 26 GHz

L7204C

7204-20T

SP4T, T, 20 GHz

L7104B

7204-26T

SP4T, T, 26 GHz

L7104C

87204-20T

SP4T, T, EL, 20 GHz

87104B

87204-26T

SP4T, T, EL, 26 GHz

87104C

SP6T (SW7-12)

7206-20

SP6T, 20 GHz

L7206B

7206-26

SP6T, 26 GHz

L7206C

7206-20T

SP6T, T, 20 GHz

L7106B

7206-26T

SP6T, T, 26 GHz

L7106C

87206-20T

SP6T, T, EL, 20 GHz

87106B

87206-26T

SP6T, T, EL, 26 GHz

87106C

Transfer (SW7-12)

7222-26

Transfer, 26 GHz

L7222C

87222-26

Transfer, EL, 26 GHz

87222C

T

ABLE

3-2:

EX72SF

S

WITCH

M

ODULES

The SPDT switches are mounted on special carriers for installation into the EX72SF and are
delivered this way if ordered separately from the factory. The SP4T and SP6T switches mount
directly in the lower openings and do not require any special carriers. The transfer switches do not
have the same square mounting plate as the multi-throw switches so they require a special carrier
for mounting in the lower round openings.

NOTE

Before proceeding with the removal and/or installation of any microwave switch modules in an
EX7000, turn the ac power switch to the OFF position and remove the ac power cord.

To remove a SPDT switch from the enclosure, simply remove the two pan head Philips screws
from each side of the individual switch faceplate. Remove the faceplate and slide the switch
forward until it is away from the enclosure and far enough out to expose the white plastic 8-pin in-
line connector. Firmly grasp each end of the white plastic body, squeezing the release tab on the
enclosure side and pull until the two parts separate.

NOTE

The new switch modules must have the cable assembly with the white plastic multi-pin connector
installed in order for it to interface with the internal control circuitry. All replacement or add-on
relays supplied by VTI Microwave will have this cable in place. Contact VTI Microwave
immediately if your switch module arrives without this cable assembly as well as the universal
mounting carrier installed.