OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR

*

80, and

*

81.

Applicable only if Relays and/or Powerline Carrier Devicess are to be used.

*

80 OUTPUT DEVICES

This is an interactive menu mode. Fill in the required data on the worksheet on below and follow

the programming procedure in the installation manual as you enter the data during the displays and prompts that appear
in sequence.

Notes:

1.

For Relays, field

*

25 must be programmed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04).

2.

For Powerline Carrier devices, field

*

27 must be programmed with a House Code.

3

. Tampers of expansion units cannot be used to operate devices.

S T A R T

=

either or both

-

S T O P

КККККККККККК

=

either or both

-

DEVICE

NUMBER

ACTION

(A)

ZONE

EVENT

LIST

(EV)

(ZL)

ZONE TYPEÊÊPART'N
SYST OP'N

No.

ККККК(ZT)

(P)

RESTORE of

ZONE LIST

(ZL)

ZONE TYPEÊÊÊÊPART'N
/SYST OP'N

No.

(ZT)

(P)

X-10

SELECT

OUTPUT RELAY
OR P.L.C.D.*

01

OUTPUT RELAY
OR P.L.C.D.*

Ê02

OUTPUT RELAY
OR P.L.C.D.*

К

К03

OUTPUT RELAY
OR P.L.C.D.*

ÊÊ04

P.L.C.D.*

КККККККК05

P.L.C.D.*

КККККККК06

P.L.C.D.*

КККККККК07

P.L.C.D.*

ККККК КК08

+

*

P.L.C.D. = Powerline Carrier Device (X-10).

Where:

X-10

SELECT

=

Powerline Carrier Device

Enter “1” if Powerline Carrier Device is being used, enter “0” if relay is being used.

A = DEVICE ACTION

0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.

EV

Ê

= EVENT

0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.

Z L

= ZONE LIST

1, 2, or 3 (from Field

*

81) or 0 = Not Used.

"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
"STOP"

RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It

need not be same list as used for START.

NOTE:

Do not use input type "BR" transmitters in a zone list to STOP a relay action, since these
transmitters do not send restores.

ZT = ZONE TYPE/SYSTEM OPERATION

Choices for Zone Types are:

00 = Not Used

06 = 24 Hr Silent

01 = Entry/Exit#1

07 = 24 Hr Audible

02 = Entry/Exit#2

08 = 24 Hr Aux

03 = Perimeter

09 = Fire Trouble

04 = Interior Follower

10 = Interior w/Delay

05 = Trouble Day/Alarm Night

24= Silent Burglary

Note

:

Any zone in "ZT" going into alarm,
fault, or trouble will actuate relay.
Any zone of that type that restores
will stop relay action.

Choices for System Operation are:

20 = Arming–Stay

38 = Chime

52 = Kissoff

21 = Arming–Away

39 = Any Fire Alarm

58 = Duress

22 = Disarming (Code + OFF)

40 = Bypassing

31 = End of Exit Time

41 = **AC Power Failure

32 = Start of Entry Time

42 = **System Battery Low

33 = Any Burglary Alarm

43 = Communication Failure

36 = **At Bell Timeout***
** Use 0 (Any) for Partition No. (P) entry.

*** Or at Disarming, whichever occurs earlier.

Note:

In normal operation mode:

Code + # + 7 + N Key Entry

starts

Device N.

Code + # + 8 + N Key Entry

stops

Device N.

P = PARTITION No.ÊÊ

1, 2, or 0 for Any