ZONE LISTS FOR OUTPUT DEVICES

This is an interactive mode. Fill in the required data on the worksheet

below and follow the procedure in the installation manual as you enter the data during the displays and prompts that
appear in sequence.
Note:

Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may
include

any or all of system's zone numbers.

Zone List 1

: Started or stopped by zone numbers (enter 00 to end entries).

,

,

,

,

,

,

,

,

,

...etc.

Zone List 2

: Started or stopped by zone numbers (enter 00 to end entries).

,

,

,

,

,

,

,

,

,

...etc.

Zone List 3

: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)

,

,

,

,

,

,

,

,

,

...etc.

Zone List 4

: Assignment of common lobby zones (enter 00 to end entries).

,

,

,

,

,

,

,

,

,

...etc.

SPECIAL MESSAGES

OC

= OPEN CIRCUIT (no communication between Console and Control).

EE

or

ENTRY ERROR

= ERROR (invalid field number entered; re-enter valid field number).

After powering up,

AC, dI

(disabled) or

Busy Standby

and

NOT READY

will be displayed after approximately 4 seconds. This

will revert to

READY

in appx. 1 minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#] + [0].

If

E4

or

E8

appears, more zones than the expansion units can handle have been programmed. Correct the programming and

then completely de-power and re-power the control to clear this indication and remove the disable indication.

TO ENTER PROGRAMMING MODE:

1.

POWER UP, then depress

[

*

] and [#]

both at once, within 50 seconds of powering up.

OR

2.

Initially, key:

Installer Code

(

4 + 1 + 1 + 2)

plus

8 + 0 + 0.

OR

3.

If different

Installer Code

is programmed, key:

New Installer Code + 8 + 0 + 0.

(if

*

98 was used to exit previously, method 1 above must be used to enter the program mode again)

TO EXIT PROGRAMMING MODE:

*

98

Exits programming mode and

prevents re-entry by: Installer Code + 8+ 0 + 0. If

*

98

is used to exit programming

mode, system must be powered down, and method 1 above used to enter the programming mode.

*

99

Exits programming mode and

allows re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press "

*

" and "#"

within 50 seconds of power up.

®