VGRT244T

24”W. Rangetop

GAS
Burner rating
• VGSB152T—Two grated

burners @ 15,000 BTU (4.4 kW)
Nat./13,500 BTU LP (4.0 kW)

• VGRT244T—Four grated

burners @ 15,000 BTU (4.4 kW)
Nat./13,500 BTU LP (4.0 kW)

• VGWT241T—One grated

burner @ 27,500 BTU (8.1 kW)
Nat./LP

• VGIB151T—One infrared grill

burner @ 21,500 BTU (6.3 kW)
Nat./20,000 BTU (5.9 kW) LP

• VGIB242T—Two infrared grill

burners, each @ 21,500 BTU
(6.3 kW) Nat./20,000 BTU (5.9
kW) LP

• Fixed piping installations

o Check with local gas utility

company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician
and in accordance with local
codes and or ordinances. In
the absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.

o An installer-supplied gas

shut-off valve must be
installed in an easily
accessible location. All
installer-supplied parts must
conform to local codes.

o Must be isolated from the

gas supply piping system by
closing its individual manual

shut-off valve during any
pressure testing of that
system at test pressures
equal to or less than 1/2 psi
(3.5 kPa).

• Natural gas models (and

LP/propane, for VGWT only)

o Water column pressure

Operating pressure—4.0”
WCP

Supply pressure of 6” –
14” WCP

If incoming pressure
exceeds 14” WCP, a step-
down regulator is required.

o Accepts standard residential

1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare
adapter.

o If using a Viking GSH12

flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.

• LP/propane models

o Water column pressure

Operating pressure—10”
WCP

Supply pressure of 11” –
14” WCP (for fixed piping
installations)

If incoming pressure
exceeds 14” WCP, a step-
down regulator is required.

o Accepts standard residential

1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.

• LP/propane tank installations

o Water column pressure

Operating pressure—10”
WCP

o Includes high-capacity

hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector

The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.

The cylinder must be
provided

with a shut-

off valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.

The cylinder supply system
must be arranged for
vapor withdrawal and
provided with a listed OPD
(overfilling prevention
device).

ELECTRICAL
• 9-volt DC battery for

electronic ignition (not
included?)

• Max. amp usage

o VGWT—0.08

PLUMBING
Not applicable

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

OUTDOOR—COOKING

Built-In Gas Side Burner, 24”W. Rangetop,

Wok/Cooker, & TruSear

Infrared Grillers

UTILITY

REQUIREMENTS

VGSB152T

Double Side Burner

VGWT241T

24”W. Wok/Cooker

VGIB151T

15”W. TruSear

Infrared Griller

VGIB242T

24”W. TruSear

Infrared Griller

Installation Requirements

Advertising
This manual is related to the following products: