Installation, Continued, Installing log set – Vanguard Heating VDVF36PP User Manual

Page 18: Gas supply testing

Advertising
background image

18

105706

DIRECT-VENT GAS FIREPLACE HEATER

VDVF36P and VDVF36ST Series

®

INSTALLATION

Continued

INSTALLING LOG SET

Before proceeding, make sure the gas con-
trol valve is in the “OFF” position. Logs
have been packaged separately to prevent
damage to glass or refractory.

1.

Remove top and bottom louvers by si-
multaneously pulling both top end
spring latches towards the center of the
appliance until they are disengaged from
locating holes. Repeat for bottom end
spring latches and pull outward. Reverse
procedure to install louvers back.

2.

Remove the screen rod by sliding
spring clip on one end toward the cen-
ter. Slide rod into screen rod hole until
other end of rod is free. Remove rod.

3.

To open the glass door, open the pairs
of latches located on the top and bottom
of the firebox (see Figure 41).

Note:

Use

caution when opening these latches.

4.

Carefully open the door. The glass door
is mounted to the firebox with 5 screws.

5.

To remove the logs from the shrink
wrap, carefully cut the plastic around
the perimeter of the log. Do not try to
remove the logs from the package with-
out first cutting the plastic.

6.

Figure 42 shows the log set. Logs “A”
have the knot at the end of the log. Logs
“B” have the knot at the middle of the
log. Twigs “C” have the shape of a “Y”.
Twigs “D” have the shape of bent twigs.
Twig “E” is a straight twig which is
placed across the top of Logs “B”.

Open

Close

Figure 41 - Removing Glass Door

GAS SUPPLY TESTING

Note:

This section is intended as a guide for

qualified service technicians installing gas
to the appliance.

CAUTION: Do not connect

appliance before pressure test-
ing gas piping. Damage to the
gas valve may result and an un-
safe condition may be caused.

OFF

P

IL

O

T

ON

L

O

H

I

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Figure 40 - Millivolt Control Valve

Pilot Gas Line - Do Not Kink

To Pilot
Burner

Pilot Adjustment Cap

ON/OFF
Knob

To Main
Burner

Flame Adjustment
Knob

Outlet
Pressure

Inlet
Pressure

The millivolt system with a manual HI/LO
applies only to the VDVF36STN/STP and
VDVF36PN/PP models. The gas control
valve is secured underneath the firebox with
two brackets fastened to the firebox bottom.
Two pressure taps are provided on the gas
control valve for a pressure gauge connec-
tion (see Figure 40).

7.

Figure 43, page 19, shows the top view
of the burner and grate.

8.

Place logs “A” as shown in Figure 44,
page 19.

9.

Place logs “B” as shown in Figure 45,
page 19. Lift the end of log “A” that will
be propped up and place log “B” under
it. At the same time, the other side of
log “B” is placed over the other log “A”.
Repeat procedure for the other log “B”.

10. Take twigs “C” (shaped like a “Y”)

and place them as shown in Figure 46,
page 19.

11. Take twigs “D” (bent twig) and place

them as shown in Figure 46, page 19.

12. Place twig “E” across the top of logs

“B” a shown in Figure 46, page 19.

13. When finished installing the logs, close

the glass doors while making certain that
the safety door switch is fully depressed
by the door frame before securing the
four (4) spring loaded latches.

14. Replace the louvers in reverse order

with the grilles pointing in the down
position.

Advertising