Rs232 protocol, Other information – VIEWSONIC VS13915-1M User Manual

Page 48

Advertising
background image

Other Information

37

ViewSonic VT3205LED

ENGLISH

1. Introduction

This document describes the hardware interface spec and software protocols of RS232 interface
communication between Viewsonic Commercial Display and PC or other control unit with RS232
protocol.
The protocol divide into three sections:
• Set-Function
• Get-Function
• Remote control pass-through mode

In below document, “PC” will represents all the control units that can sent or receive the

RS232 protocol command.

2. Description

2.1 Hardware specification

Viewsonic LCD communication port in the rear side
(1) Connector type: DSUB 9 Pin Male
(2) Pin Assignment

Male DSUB 9Pin

(outside view)

1 2 3 4 5

6 7 8 9

Pin #

Signal

Remark

1

NC

2

RXD

Input to LCD Monitor

3

TXD

Output from LCD Monitor

4

NC

5

GND

6

NC

7

NC

8

NC

9

NC

frame

GND

* Use of crossover (null modem) cable required for use

with PC.

2.2 Communication Setting

• Baud Rate Select: 9600bps (fixed)
• Data bits: 8bits (fixed)
• Parity: None (fixed)
• Stop Bits: 1 (fixed)
2.3 Command Message Reference

PC sends to Monitor command packet followed by “CR”. Every time PC sends control command to
the Monitor, the Monitor shall response as follows:
1. If the message is receives correctly it will send “+” (02Bh) followed by “CR” (00Dh)
2. If the message is receives incorrectly it will send “-” (02Dh) followed by “CR” (00Dh)

RS232 Protocol