Other information – VIEWSONIC VS13915-1M User Manual
Page 50
Advertising

Other Information
39
ViewSonic VT3205LED
ENGLISH
Reply (Command Type= “+” or “-”)
Name
Length
ID
Command
Type
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
(Command Type= “+” or “-”, Only for HDTV power on)
Name
Length
Command
Type
CR
Byte Count
1 Byte
1 Byte
1 Byte
Bytes order
1
2
3
Example1: Set HDTV power on and this command is valid.
Send (Hex Format)
Name
Length
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x36
0x73
0x21
0x30
0x30
0x31
0x0D
Reply (Hex Format)
Name
Length
Command
Type
CR
Hex
0x32
0x2B
0x0D
Example2: Set Brightness as 76 for TV-02 and this command is valid.
Send (Hex Format)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x36
0x0D
Reply (Hex Format)
Name
Length
ID
Command
Type
CR
Hex
0x34
0x30
0x32
0x2B
0x0D