Sealed burner, Figure 3-33 – Whirlpool 4322452 User Manual

Page 42

Advertising
background image

Page 3-24

PRESSURE

REGULATOR

GAS INLET

IGNITOR

SPARK

MODULE

AIR SHUTTER

GAS VALVE

IGNITOR SWITCH

VENTURI

BURNER

CONTROL

KNOB

GAS

MANIFOLD

SPARK
IGNITOR

BURNER CAP

TO SPARK

IGNITOR

SPARK

BURNER

BURNER FLAME

GAS FLOW

120 VAC

LINE VOLTAGE

GAS FLOW

HIGH VOLTAGE

PULSES

OFF

LITE

4

7

9

8

10

2

5

6

1

3

SEALED BURNER

When a main burner control knob q is turned to the “lite” position, the gas valve r opens, and
gas flows through the pressure regulator s into the manifold t through the open valve. As gas
passes through the valve and its orifice, it is directed into the venturi u, where it mixes with
primary air to create the proper mixture necessary for combustion.

At the same time, line voltage is applied through the ignitor switch v, to the ignitor spark mod-
ule w, which produces high-voltage pulses to all of the spark ignitors x. The pulses cause a
spark y to occur between the spark ignitor electrode, and the grounded burner cap z. The
gas and air mixture at the burner head is ignited by the spark, and a flame is produced at each
of the top burner ports.

Refer to Figure 3-33 for the following sequence.

Figure 3-33

Advertising