background image

Page 4-9

Gas Outlet

(To Oven Burner)

No Current Flow -

Valve Is Closed

Gas Inlet

(From Regulator)

120 Volt

Supply Terminal

Safety Valve

Bimetal & Heater Coil

Figure 4-16

Gas is available at the safety valve at all times, but can be shut off by a manual shutoff valve on
the regulator (see Figure 4-17).

Manual Gas

Shutoff Valve

Safety

Valve

Pressure

Regulator

Figure 4-17

The oven uses a

Single Safety Valve

that is bimetal-operated (see Figure 4-16). It has one gas

inlet and one gas outlet, for the combination Bake and Broil burner. The safety valve uses an
electrically-operated device at the gas outlet to control the gas flow to the oven burner. The device
consists of an electric heater coil wrapped around a bimetal strip. One end of the bimetal is riveted
to the plate of the valve. The other end has a rubber seat attached to it that covers the gas outlet.
At room temperature, the spring force of the bimetal presses the rubber seat against the gas outlet.