SET HEAT ANTICIPATOR

Set anticipator to match the setting of your old thermostat you
noted in Step 3, or, the anticipator should be set to match the
current rating stamped on your main heating control. The heat
anticipator is adjustable from 0.15 to 1.2 amps. Adjust the antici-
pator by rotating the contact arm (see fig. 5). The anticipator
setting is indicated by the numbers on the base that the pointer
points to. If you are unsure where to set the anticipator contact the
heater manufacturer for a recommended setting.

Move the pointer

counterclockwise to lengthen

heating system

cycles; move

clockwise to shorten

heating cycles. Adjustments

should not be greater than 1/2 marking at a time.

Snap on Cover: Carefully align the cover with the base and snap
the cover onto the base.

NEW THERMOSTAT OPERATION

1C20 Heat Only –

After power is turned on, slide temperature

lever to desired setting. To turn heat off, slide lever all the way to
the left until it clicks.

1C26 –

This thermostat is easy to operate. Fig. 6 shows how the

heating/cooling system and fan operate when the switches are in
various positions. After power is turned on, use the system switch
to select either heating or cooling, or to turn the heating/cooling
system off. Use the fan switch to control fan operation. When the
fan switch is in the

AUTO

position, the fan will cycle with the

heating or cooling system (the fan will not run if the system switch
is in the

OFF

position and the fan switch is in the

AUTO

position).

When the fan switch is in the

ON

position, the fan will run

continuously, regardless of system switch position (even if the
system switch is set to

OFF

, the fan will run if the fan switch is in

the

ON

position).

ELECTRICAL DATA
Switch Rating

........................ 24 VAC (30 VAC max.)

Heating .................................... 0.15 to 1.2 Amps
Cooling .................................... 0 to 1.5 Amps

Switch Action

........................ Snap Action

Anticipator Rating:

Heating .................................... Adjustable from 0.15 to 1.2 Amps
Cooling .................................... Fixed

SPECIFICATIONS

THERMAL DATA:
Temperature Range ..............

50°F to 90°F (10°C to 32°C)

Operating Humidity Range ...

0 – 90% noncondensing

24VAC
50/60 Hz
.35 Amps

Typical Zone Valve

24VAC
50/60 Hz
.23 Amps

Typical Gas Valve

24VAC
50/60 Hz
.43 Amps

Typical Oil Primary

www.white-rodgers.com

5

6

7

Figure 5. Anticipator adjustment

Rotate contact arm
to adjust heat anticipator

Arrow points to the
current rating of
the primary coontrol

NOTE

For Milivolt Application:

Rotate contact arm

to rest on this rivet.

FAN

AUTO

ON

SYSTEM

COOL OFF HEAT

Shows switch position

OPERATION

No heating; no cooling; no fan

No heating; no cooling; fan runs continuously

Cooling system cycles from thermostat; fan runs
continuously

Cooling system and fan cycle from thermostat

Heating system cycles from thermostat; fan cycles
from fan control on furnace

Heating system cycles from thermostat; fan runs
continuously

Figure 6. Subbase switching and thermostat/system

operation (1C26 only)