CONVERTING THE DEEP WELL PUMP TO
SHALLOW WELL OPERATION (FIGURE 9)

For shallow wells (25 feet or less), a
bolt-on shallow well jet is available as
an accessory for deep well pumps. The
jet attaches to the front of the pump
with the two bolts provided and con-
verts the deep well pump into a shal-
low well pump. The shallow well jet has
a 1” NPT inlet and a 1/8” NPT opening
for an air volume control. For optimum
performance, an incline check valve on
the inlet side of the shallow well jet is
recommended

Electrical

Risk of electrical
shock. This pump is

designed for indoor installation only.

The voltage of power supply must
match the voltage of the pump. All
above ground well pumps except

5

Operating Instructions and Parts Manual

JCU50

Pressure
Switch

Figure 8 - Precharged Storage Tank

Pressure
Switch

Figure 6 - Horizontal Tank

Figure 7 - Vertical Tank

Air
Volume
Control
Tubing

Air
Volume
Control

Air Volume Control

Hose
Coupling

Air
Volume
Control
Tubing

Distance In Feet

From Meter To Motor

Dual

0

51

101

201

Element

To

To

To

To

Fuse

50

100

200

300

HP

Volt

250V

Wire Size

115

15

14

14

12

10

230

10

14

14

14

14

115

15

14

14

10

8

230

10

14

14

14

14

115

20

12

12

10

8

230

10

14

14

14

14

CHART 3 - RECOMMENDED FUSE & WIRING DATA - 60 HZ MOTORS

1/2

3/4

1

To Air Volume

Control

Figure 9 - Shallow Well Jet

Jet

www.waynewatersystems.com

Installation

(Cont’d)

3. Install a valve and isolating hose

between the system and the house
plumbing to aid in pump removal for
servicing and for reducing noise trans-
mitted through the house piping.

4. Provide a hose bib (faucet) at the

lowest point in the system to drain
for service or storage.

DEEP WELL PUMP WITH PRECHARGED
STORAGE TANK (FIGURE 8)

1. Check tank precharge using a tire

pressure gauge. The precharge pres-
sure should be 28 - 30 psi on 1/2, 3/4
and 1 HP models.

2. Check the pressure with the power

off, faucets open and no water
flowing (zero water pressure).

3. Install a valve and isolator hose

between the system and the house
plumbing to aid in pump removal
for servicing and for reducing noise
transmitted to the house through
the piping.

4. Provide a hose bib (faucet) at the

lowest point in the system to drain
for service or storage.

SWS50BOOST have dual voltage motors
preset at the factory to 230 volts. The
motors can be converted to 115 volts by
turning the voltage selector to the
desired voltage (See Figure 10). Use a
needle nose pliers to pull the selector
out approximately 1/4”, rotate and
then reinsert in correct position.

Select the proper size wire and fuse
(Chart 3). Time delay fuses are recom-
mended over standard fuses for motor
circuit protection. All pump motors
have built-in automatic overload pro-
tection that will prevent damage to the
motor due to overheating.

Do not connect to
electric power sup-

ply until unit is permanently grounded.
Connect ground wire to approved ground
then connect terminal provided.

A metal underground water pipe or
well casing at least 10 feet long makes
the best ground electrode. If plastic
pipe or insulated fittings are used, run
a wire directly to the metal well casing
or use a ground electrode furnished by
the power company.