Wayne 360516-001 User Manual

Pedestal sump pump, Assembly, Description

Advertising
background image

Operating Instruction and Parts Manual

Pedestal Series

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain

the product described. Protect yourself and others by observing all safety information. Failure to comply with

instructions could result in personal injury and/or property damage! Retain instructions for future reference.

For parts, product & service information

visit www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

360516-001 9/09

© 2009 Wayne Water Systems

Pedestal Sump

Pump

FLOAT INSTALLATION SPV800, SPV500
& SSPTU50
1. To attach float for SPV800, SPV500

& SSPTU50. insert float rod through
hole in switch lever.

2. Place rubber grommet on float rod

in temporary position.

3. Slide float guide onto float rod.
4. Using pliers to hold the float rod,

screw the float on.

5. Attach the float guide to pump

halfway up the pumps stand and
properly align with motor switch.

FLOAT INSTALLATION PTU30, PTU33A
& PTU50
1. To attach float for PTU30, PTU33A, and

PTU50 begin by sliding the float guide
onto the open end of the float rod.

2. Next slide a grommet onto the open

end of the float rod about ¼ of the
way down.

3. Guide the open end of the float rod

through the hole in the switch lever.

4. Place the second grommet onto the

open end of the float rod, being sure
to keep the float rod inserted into the
switch lever.

5. Attach the float guide to pump halfway

up the pumps stand and properly align
with motor switch.

NOTE: For all replacement float kits
installation will be the same as for
SPV800, SPV500 & SSPTU50.

GENErAL SAFETy INFOrMATION
Read these rules and
instructions carefully. Failure
to follow these instructions
could cause serious bodily
injury and/or property damage.

Do not submerge

motor or allow

motor to be exposed to water. Personal
injury and/or death could result.

Do not

use to

pump flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not
use in a flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or death could result.

This pump is not

designed to handle

salt water, brine, laundry discharge or
any other application which may contain
caustic chemicals and/or foreign materials.
Pump damage could occur if used in these
applications and will void warranty.

All wiring must be

performed by a

qualified electrician.

If the

basement

has water or moisture on the
floor, do not walk on wet area
until all power is turned off. If
the shut-off box is in the basement, call
an electrician to disconnect the power.
Remove pump and either repair or replace.
Failure to follow this warning could result
in fatal electrical shock.

A battery backup

system should be

used. Please contact your local retailer
to order an emergency backup system.

Assembly

Always

disconnect

the power source before
attempting to install, service,
relocate or maintain the pump.
Never touch sump pump, pump motor,
water or discharge piping when pump is
connected to electrical power. Never handle
a pump or pump motor with wet hands or
when standing on wet or damp surface or
in water. Fatal electrical shock could occur.

Description

The pedestal pump is designed for
home sump applications. The unit is
equipped with an 8-ft long, 3-prong
grounding type power cord. Motor is
air cooled; it is not designed to operate
under water. A float switch is provided
for automatic pump operation. This
pump is not suitable for aquatic life.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components are
damaged, return the unit to the place of
purchase for replacement. Failure to do so
could result in serious injury or death. Some
warning labels come affixed to the pump.
Over time, these labels may fade. If this
happens, contact Wayne Water Systems for
a free replacement label.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

Danger indicates

an imminently

hazardous situation which, if not avoided,

will result in death or serious injury.

Warning indicates

a potentially

hazardous situation which, if not avoided,

could result in death or serious injury.

Caution indicates a

potentially hazardous

situation which, if not avoided, may result

in minor or moderate injury.

Notice indicates

important

information, that if not followed, may

cause damage to equipment.

General Safety

Information

CALIFOrNIA PrOPOSITION 65

This product or its

power cord may

contain chemicals, including lead, known
to the State of California to cause cancer
and birth defects or other reproductive
harm. Wash hands after handling.

MANUAL

24 in.

Min.

14 in.

Dia.

Min.

Figure 1

Switch

Grommet

Float Rod

Guide

Float

GFCI Grounded

Outlet

Advertising
This manual is related to the following products: