Operating Instructions and Parts Manual

www.waynepumps.com

so that the pump switches on with
approximately 14” of water in the sump.

3. While the pump is draining the pit,

verify that the discharge piping is
carrying the water to a point several
feet away from the foundation.

4. If the pump discharge line is

exposed to freezing temperature,
the exposed line must be pitched to
drain. Trapped water will freeze and
damage the pump.

Maintenance

Always

disconnect the electrical
supply before attempting to
install, service, relocate or
perform any maintenance. If the power
source is out of sight, lock and tag
in the open (off) position to prevent
unexpected power application. Failure
to do so could result in fatal electrical
shock. Only qualified electricians should
repair this unit. Improper repair could
result in fatal electrical shock.

1. Disassembly of the motor prior to

expiration of warranty will void the
warranty. If repairs are required, see
troubleshooting chart.

2. Keep pump inlet clean and free

of all foreign objects and inspect
annually. A clogged inlet will
damage pump.

3. Check pump monthly for proper

operation.

NOTE: A pump that has a tripped
thermal protector may start suddenly!

Installation

1. A ground fault circuit interrupter

(GFCI) is required.

2. This pump is for use on 120 Volt

(single phase), 60 hz, 15 amp service
and is equipped with a 3 conductor
cord and a 3 prong grounding plug.

3. Install pump in a sump pit with

minimum size as shown (See Figure
1). Construct sump pit of tile,
concrete, steel or plastic.

4. Locate unit on a solid, level

foundation. Do not place pump
directly on clay, earth, gravel or
sandy surface. These surfaces contain
small stones, gravel, sand, etc. that
may clog or damage the pump and
cause pump failure (See Figure 1).

5. (Optional) Thread check valve (not

included) into pump body carefully
to avoid stripping or cross threading.
Do not use pipe joint sealant.

6. Connect 1-1/4” rigid pipe to rubber

boot on check valve. Reverse boot
for 1-1/2” diameter pipe. Tighten
hose clamps.

Support pump and

piping when

assembling and after installation. Failure
to do so could cause piping to break, pump
to fail, etc. which could result in property
damage and/or personal injury.

Flood risk. If

flexible discharge

hose is used, make sure pump is
secured in sump pit to prevent
movement. Failure to secure pump
could allow pump movement and switch
interference and prevent pump from
starting or stopping.

IMPOrTANT: Make sure there is
adequate room for float switch to move
freely during operation.
7. Protect electrical cord from sharp

objects, hot surfaces, oil and
chemicals. Avoid kinking the
cord and replace damaged cords
immediately.

8. A sump pit cover must be installed

to prevent debris from clogging or
damaging the pump.

Risk of

electrical

shock! This pump is supplied
with a grounding conductor
and grounding type attachment plug. Use
a grounded GFCI receptacle to reduce the
risk of fatal electrical shock.

Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the
pump inoperable.
9. Insert the float switch cord plug

directly into a 120 volt outlet (See
Figure 2).

ADjUST AND T EST
1. Fill sump with water.
2. Adjust rubber grommet into a

permanent position on float rod

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or
run

1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective switch
5. Impeller
6. Float obstructed

1. If blown, replace with proper sized fuse or reset breaker

2. If voltage is under 108 volts, check wiring size

- DO NOT USE AN EXTENSION CORD

3. Replace motor or pump
4. Replace switch
5. If impeller will not turn, remove housing and remove blockage
6. Make sure float moves freely up and down

Pump start and stops too
often

1. Back flow of water from piping
2. Float out of adjustment

1. Install or replace check valve (Wayne check valve kit #66005-WYN1)
2. Adjust grommet

Pump will not shut off
or thermal protector
turns off

1. Defective switch
2. Obstacle in piping
3. Float obstructed

1. Replace switch
2. Remove pump and clean pump and piping
3. Make sure float moves freely up and down

Pump operates but
delivers little or no
water

1. Low line voltage

2. Plugged impeller

1. If voltage is under 108 volts, check wiring size

- DO NOT USE AN EXTENSION CORD

2. Clean out impeller

Grounding

Blade

Grounded

Outlet

Power

Cord

TEST

RESET

Figure 2

GFCI

Outlet