Diagterm terminal (commands), Table 3.2, Figure 3.3 – Wegener Communications IPUMP 562 User Manual

Page 25

Advertising
background image

www.wegener.com

800092-01 Rev. A

15

Unity 552 User’s Manual

indicate that, although output is being produced, there is a problem that could require
attention. The most common conditions that produce alarms or warnings are listed in

Table

3.2

.

Table 3.2: iPump 562 Front Panel Status LED Alarm and Warning Indications

Diagterm
Terminal
(Commands)

The Serial Port (RS-232) can be used to connect to a terminal console. After the IRD is
powered on, a diagterm command-line interface (CLI) can be used to monitor and control
the system. For more information on diagterm and syntax of the individual commands,
please see an appendix.

Figure 3.3

illustrates the

Help

screen on the diagterm terminal.

Figure 3.3: Diagterm Terminal Help Screen

Mode

LED Status

Condition

Alarm

Red blink = 2

No carrier

Red blink = 3

No RF signal

Red blink = 4

In recovery

Red blink = 5

Eb/No alarm

Red blink = 11

Not authorized

Warning

Amber blink = 1

No response from SEC_MICRO

Amber blink = 2

Marginal Eb/No

Amber blink = 4

Selected audio not available

Amber blink = 5

RF too low

Amber blink = 6

RF too high

Amber blink = 7

Application download failed

Normal

Green

Normal operation